[ 01 ]Power Generation· POWER GENERATION

Power Generation: Time Sync & Timing Security

Unified time bases and satellite-timing protection for SCADA, DCS, PMU, smart meters and operational dispatch in thermal, hydro, nuclear and renewable power plants.

Related Products
[ 02 ]About· ABOUT

Sector Overview

For SCADA, DCS, PMU, smart meters, and ops dispatch in thermal, hydro, nuclear, and renewables, Yinzhong provides unified time bases and GNSS protection.

Generation-Side Timing Needs

  • DCS / SCADA — plant-wide time, accurate SOE ordering
  • Protection — fault recording ≤ 1 ms
  • PMU — phasor sync ≤ 1 μs (GB/T 26865.2)
  • AGC / AVC — consistent with provincial dispatch
  • Metering — gate-meter time traceability
  • Operations — control room procedures aligned

By Source

Thermal / gas turbine

  • Distribution across control building + boosting + coal handling + water plant
  • DCS integration (Siemens / Beijing Hollysys / SUPCON)
  • Control-room giant time display

Hydro

  • Harsh outdoor environment, lightning exposure
  • Synchronisation across intake tunnel / dam / powerhouse
  • BeiDou short-message for emergency comms

Nuclear

  • Multi-layer consistency: main control / DCS / EDG / RPS
  • Time separation between safety and non-safety class

Renewables (PV / wind)

  • Booster / SVG / storage unified
  • Remote ops time consistency
  • Cross-province sync with dispatch

Yinzhong Stack

  • Master/slave — YZ-9810, IRIG-B / PTP / NTP / 1PPS
  • Protection — YZ-9770 for renewable outdoor sites
  • Monitoring — YZ-9100 feeding plant "Two Tickets, Three Systems" inspections
  • DCS adapters — ABB 800xA / Emerson Ovation / Siemens / Guodian iSmart
[ 03 ]Pain Points· PAIN POINTS
01

Inconsistent event-sequence timestamps between DCS and SCADA make post-incident reconstruction unreliable

02

Plant-level monitoring, smart meters and protection devices use a tangle of timing protocols — high commissioning and O&M costs

03

National Class-II counter-terrorism sites have explicit timing-security requirements; relying on open GPS alone is no longer compliant

04

New / retrofit plants need to layer next-gen timing systems on top of running equipment without downtime

[ 04 ]Capabilities· SOLUTION CAPABILITIES
01

All-Protocol Outputs

Concurrent IRIG-B(DC/AC), PPS/PPM/PPH, NTP, PTP, DCF77 and serial-text outputs — covers every DCS/SCADA/relay/metering timing port

02

Timing Security

YZ-9770 satellite signal security device detects and isolates spoofing, jamming and suppression — meets the "electronic protection" requirement for Class-II counter-terrorism sites

03

Hot-Standby Upgrade

Supports running new and legacy devices in parallel for staged migration with zero-downtime cutover

04

Optional Holdover

Choice of OCXO or rubidium atomic clock — sustains long-duration high-accuracy holdover under GNSS denial

[ 05 ]Case Studies· CASE STUDIES
01LIVE

Thermal Plant Timing Security

Configured YZ-9770 timing security devices on anti-drone systems at multiple thermal plants, safeguarding the authenticity of dispatch time bases.

ThermalAnti-droneTiming Security
02LIVE

Hydro Class-II Counter-Terrorism Compliance

Deployed electronic-protection timing security per GA1800.3 (Counter-Terrorism Requirements for Power Systems — Part 3: Hydropower Enterprises).

HydroGA1800.3Class-II Compliance
Talk to engineering

Find the right model

Our engineers combine your site topology, protocols and alarm logic to recommend the right model and customisation.

Browse all products